Options of Remote Management in IGEL OS 12
This article shows how to enable the logging of remote management events in IGEL OS 12.
The logged events can be found both in the UMS Console and the UMS Web App. For more information, see (12.05.100-en) View Device Information in the IGEL UMS.
Menu path: System > Remote Management > Options
Log login and logoff events
☑ Details of logon and logoff events of the following logon types are sent to the UMS:
Active Directory/Kerberos
Single Sign-On
Local User
Guest User
Events are only logged if the Enable user logon history parameter is enabled in the UMS Console, under UMS Administration > Global Configuration > Misc Settings. For more information, see (12.05.100-en) Misc Settings in IGEL UMS.
☐ Logon and logoff events are not sent to the UMS. (Default)
Ranking of connectors
Defines the order in which the device connects to the configured device connectors based on their connector types. Connector types are listed in System > Remote Management > Universal Management Suite.
Possible options:
no preference (default)
The device connects randomly to any configured device connector, regardless of the connector type.prefer UMS
The device will try to connect to the UMS Servers first (that is, the connections listed with the ums connector type are contacted first).
The device will only try to connect to an ICG, if UMS Servers are not reachable or configured.prefer ICG
The device will try to connect to an ICG (that is, the connections listed with the icg connector type are contacted first).
The device will only try to connect to a UMS server, if no ICG is reachable or configured.