(12.04.120) How to Edit Profiles in the IGEL UMS
In the IGEL Universal Management Suite (UMS), you can edit the existing profiles. You can edit the description data of a profile as well as the profile configuration.
Menu path: UMS Console > Profiles
How to Edit Description Data of a Profile
Description data consist of the name of the profile, a descriptive text, the firmware version this profile is based on, and the overwrite flag for sessions.
To edit these settings:
Under Profiles, select the required profile.
Change the settings according to your needs.
Â
To save the changes, click or Edit > Save description.
The data are now updated in the database.
How to Edit the Profile Configuration
To edit the profile configuration, proceed as follows:
Under Profiles, select the required profile and click [context menu] > Edit Configuration or Edit > Edit Configuration.
Or you can simply double-click the required profile.
The configuration dialog will open.Â
To change settings, click on the activation symbol in front of the parameter until the desired function is active:
- The parameter is inactive and will not be configured by the profile.
- The parameter is active and will be configured by the profile. Template keys are inactive.
- Reset to the default value.
The following activation symbols are only displayed if template profiles are activated (see (12.04.120) Template Profiles in the IGEL UMS ):- The parameter is active and will be configured by the profile. Template keys are active.
- The parameter is active and will be configured by the profile using a template key.
Â
Save the changes.
Determine when the changes should take effect – immediately or at the next reboot of the device.