Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »

General

Browse

Visibility of the object in the structure tree (path as far as the object must also be allowed!)


Read

Read permission in respect of folder contents and object attributes


Move

Devices can be moved without write permission.


Edit configuration

Write permission for the configuration of a device (Setup)


Write

Write permission in respect of folders and object attributes (not Setup)


Edit System InformationThe system information of a device (device attributes) can be edited.


Access Control

The permission settings for the object can be changed.


Remote access

VNC / secure terminal access to the device


Send message

Messages may be sent to devices.


Assignment

Assign (priority) profile

A profile may be assigned to the object.

This permission is required for the assignment of apps for IGEL OS 12 devices.


Assign file

A file may be assigned to the object.


Assign Base System / Firmware Update

An IGEL OS Base System app / firmware update may be assigned to the object.


Assign FWC

A firmware customization can be assigned to the object.


Assign Template Value / Value GroupA template value / value group can be assigned to the object.

Power Control

Reboot

Rebooting the device.


Suspend

Putting the device into the idle state.


Shutdown

Shutting down the device


Wake up

Waking up the device using wake-on-LAN.


Firmware Control

Update

The app / firmware update may be carried out.


Reset

Resetting the device to the factory defaults.


Flash player

Downloading a Flash Player plugin for Firefox


File transfer

An assigned file may be transferred to the device.


Generic commandGeneric commands (e.g. specific device commands like Deploy Jabra Xpress package) can be sent to the device.

Settings ControlUMS -> DeviceThe configuration of the UMS may be sent to the device.

Device -> UMSThe local configuration of the device may be read to the UMS.
  • No labels