If a backup of the embedded database is available (see Creating a Backup of the IGEL UMS ), just restore the backup, see Restoring a Backup.

Restoring a File-Based Backup

...

  1. Open the UMS Administrator, and go to Datasource in the menu on the left.

Include Page
ENLITEUMSP:_Path for the UMS AdministratorENLITEUMSP:
_Path for the UMS Administrator

...

  1. In the Datasource area, delete the corrupted Derby DB.

  2. Create a new embedded DB with exactly the same user name and password as you used for the deleted DB.

  3. Deactivate the newly created DB.

  4. Stop the UMS Server service. For details on how you can stop it, see IGEL UMS HA Services and Processes.

  5. Erase all files contained in the folder at RMDB_PATH.

  6. Copy your previously backed-up files to RMDB_PATH.

  7. Activate the DB with the UMS Administrator under Datasource.

  8. Wait 1 - 2 minutes, then log in to the UMS Console.

...