(12.06.110-en) Creating Profiles in the IGEL UMS
In the following article, you will learn how to create profiles in the UMS Console. You will also find here the information on Overwrite sessions and other expert mode settings for profiles.
For how to create profiles in the UMS Web App, see How to Create and Assign Profiles in the IGEL UMS Web App.
Menu path: UMS Console > Profiles
Profiles for IGEL OS 12 and IGEL OS 11 Devices
The procedure for creating profiles for IGEL OS 12 and IGEL OS 11 devices is different. If you want to configure, for example, Chromium browser settings for your IGEL OS 12 and IGEL OS 11 devices, you have to create two profiles – one for OS 12 devices and another for OS 11 devices.
Profiles for IGEL OS 12 devices can only be created and changed in the UMS Web App. It is not possible to create/edit them in the UMS Console.
Profiles for IGEL OS 11 devices can be created and edited in the UMS Console and the UMS Web App.
The direct assignment of OS 12 profiles to OS 11 devices is not possible, and vice versa. If you assign an OS 12 profile to an OS 11 device indirectly, i.e. via a directory structure, the settings from the OS 12 profile are ignored for the OS 11 device (and vice versa).
To ensure that you can use all new features of IGEL OS:
→ Update your UMS to the current version.
→ For all relevant OS 11 profiles, set Based on to the appropriate firmware version.
→ For OS 12 profiles, note the following: An OS 12 profile configures ALL versions of an app, unless a specific version is set under Show Versions.
For a better overview, it is recommended to organize profiles using subdirectories.
How to Create a Profile
To create a new profile, proceed as follows:
In the UMS Console, click Profiles > [context menu] > New Profile or System > New > New Profile.
Alternatively, you can import a previously created profile. See Exporting and Importing Profiles.
The New Profile window will appear.Enter a Name and a Description for the profile.
Under Based on, select a firmware version for the new profile.
Optional (usually not required): Click Expert mode to define the following settings:
Inherits Settings from: You can specify here whether the new profile should use settings from an existing profile or device. If yes, select the required profile / device from the list.
Activate no settings: Initially, there are no active parameters. (Default)
Activate all settings: All available parameters of the profile will be active.
Overwrite sessions: All free instances will be overwritten by the profile.
Click OK to set up and save the profile.
Configure the desired settings.
To change settings, click on the activation symbol in front of the parameter until the desired function is active.
- The parameter is inactive and will not be configured by the profile.
- The parameter is active and will be configured by the profile. Template keys are inactive.
- Reset to the default value.
The following activation symbols are only displayed if template profiles are activated (see (12.06.110-en) Template Profiles in the IGEL UMS ):
- The parameter is active and will be configured by the profile. Template keys are active.
- The parameter is active and will be configured by the profile using a template key.Save the settings:
Click Apply and send to device to save the settings without quitting the profile.
Click Save to save the settings and quit the profile.
Assign the profile to the required devices / device directories. See How to Allocate IGEL UMS Profiles.
New Profile: Expert Mode
The options in the window New Profile > Expert mode have the following meaning:
Inherits Settings from
Defines if the new profile inherits settings from an existing profile or device.
Activate no settings
No parameters are initially active.
Activate all settings
All available parameters for the profile are enabled. Note that all settings are locked on the device with a lock symbol. A profile with Activate all settings option enabled prevents settings from being changed locally on the device. This option makes sense only if you would like to have all settings for a device managed on the basis of this profile.
Overwrite sessions
☑ Overwrites the free instances defined on the device or assigned via other profiles with those of this profile.
☐ The free instances defined in the profile are added to the free instances that were defined previously on the device or by the assignment of other profiles. (Default)
The Overwrite sessions option ensures that only the free instances for this profile are created on the device. Free instances created in other profiles or directly in the device configuration are disabled.