Document toolboxDocument toolbox

(12.01-en) Automating the Rollout Process in the IGEL UMS

You want to set up the IGEL Universal Management Suite (UMS) in such a way that new devices will be stored directly in the correct directory and the right configurations will automatically be assigned to them. With Zero Touch Deployment in the rollout, devices will be configured automatically according to the profiles, with almost zero management outlay.


The idea of Zero Touch Deployment means automatic device registration with automatic assignment of profiles by default directory rules.

In the end, the device will automatically be registered in the UMS, assigned to the right directory, and related to the valid profiles. To prepare this automated process, you have to go the other way around. First, define the profiles, then assign them to the directories, then create default directory rules and automate the registration.

Preparing Automatic Rollout

Configure your device globally, indirectly assigning profiles by a parent directory:

  1. Create a new root directory, e.g. IGEL OS.
    For how to create a device directory, see (12.01-en) Creating a Directory in the IGEL UMS.

  2. Assign certain profiles to this root directory, e.g. Security.
    For how to assign profiles, see (12.01-en) How to Allocate IGEL UMS Profiles. See also (12.01-en) Prioritization of Profiles in the IGEL UMS.
    For detailed information on profiles, see (12.01-en) Profiles in the IGEL UMS.

  3. Move your devices or your directories containing devices to this root directory.
    These devices will inherit the profiles assigned to the root directory.

    Example: Devices that will be placed to the directory Augsburg during the registration will inherit the profile Security which is assigned to the root directory IGEL OS:

Automating the Rollout

  1. Click UMS Administration > Global Configuration > Default directory rules to create a new default directory rule.
    For detailed information on default directory rules, see (12.01-en) Default Directory Rules.

  2. Choose the directory in which you want to store the devices according to the rule.




  3. Configure your DNS or DHCP server and activate the automatic registration of devices as described under (12.01-en) Registering Devices Automatically on the IGEL UMS.

    We recommend disabling automatic registration after the rollout, so that no unknown devices will be registered without your control and could obtain sensitive settings.



  4. Start your devices. They will be automatically registered on the UMS Server.
    Thanks to the default directory rule, these devices will be stored in the right directory and will automatically receive the correct profiles.

    Example:

Related Topics

If you want to use structure tags for automating the rollout: (12.01-en) Using Structure Tags

If you have problems with the device registration: (12.01-en) Troubleshooting: Registration of a Device via Scanning for Devices Fails