You have a multi-instance IGEL Universal Management Suite (UMS) installation and want to know which files are automatically synchronized between the servers.

...

Prerequisites

  • A High Availability (HA) environment with UMS version 6.06.100 or higher

  • A Distributed UMS installation with UMS version 6.10.100 or higher

General Overview

The following files are synchronized between the UMS Servers automatically:

The objects are synchronized immediately – unless a UMS Server is temporarily unreachable. In that case, the synchronization takes place every 5 minutes or at server startup.

The synchronization applies to the file system and does not refresh the view in any UMS Console other than the one in which the object has been created. Thus, you may need to press [F5] or the refresh button

...

image-20240614-162212.pngImage Added to view the object in the UMS Console on the other server.

Include Page
ENLITEUMSP:_UMS HA: No Time Difference Warning
ENLITEUMSP:_UMS HA: No Time Difference Warning

Anchor
UFU_sync_HA
UFU_sync_HA
Synchronization of Universal Firmware Updates

To enable the automatic synchronization of the firmware updates between the UMS Servers, proceed as follows:

  1. In the UMS Console, go to UMS Administration > Global Configuration > Universal Firmware Update.

  2. Activate Synchronize downloaded Universal Firmware Updates within UMS WebDAV directories.

    Image Modified

  3. When adding a firmware update under Universal Firmware Update > [context menu] > Check for new firmware updates, set a WebDAV directory as a target path for the download.

    Image Modified

When the download is complete, you can see under Synchronization Status the servers for which the firmware update has already been synchronized.Image Removed

...

Note

Universal Firmware Updates are synchronized between the UMS Servers only if HTTPS (UMS WebDAV) or HTTP (UMS WebDAV) is selected under Protocol. These protocols are used for transferring the firmware update files from the UMS WebDAV directory to the devices. 

Image Modified

With any other protocol, firmware updates are not synchronized between the servers.

Connection Data Used during the Update

...

The connection information contains

  • a Public Address if it is configured for the server under UMS Administration > UMS Network > Server > [server's context menu] > Edit. Otherwise, the stored hostname is used.

  • a Public Web Port if it is configured for the server under UMS Administration > UMS Network >

    Server > 

    Server > [server's context menu] > Edit. Otherwise, the stored web port is used.

    Image Modified